Air King 9718

Air King 9718 18-Inch Industrial Grade Ceiling Mount Fan User Manual

Model: 9718 | Brand: Air King

1. Introduzzjoni

This manual provides instructions for the safe installation, operation, and maintenance of your Air King 9718 18-Inch Industrial Grade Ceiling Mount Fan. This fan is designed for powerful air movement in industrial and commercial spaces such as garages, fitness centers, offices, and schools. It features an 18-inch blade, a 1/6 HP motor, and three speed settings, providing up to 8780 CFM of airflow. The fan head can be pivoted for directional airflow. The unit is constructed with powder-coated steel for durability and includes a ceiling mount bracket and a secondary safety cable.

Air King 9718 18-Inch Industrial Grade Ceiling Mount Fan, front view

Figura 1: Quddiem view of the Air King 9718 Industrial Grade Ceiling Mount Fan.

2. Istruzzjonijiet Importanti dwar is-Sigurtà

Read all instructions carefully before using this fan. Failure to follow these instructions may result in electric shock, fire, or serious personal injury.

  • Always disconnect the fan from the power source before cleaning, servicing, or moving.
  • Ensure the fan is securely mounted to a structural support capable of holding its weight (23.1 lbs).
  • Use the provided secondary safety cable as an additional safety measure during installation.
  • Tħaddem ebda fann b'korda jew plagg bil-ħsara. Armi l-fann jew erġa' lura f'faċilità ta' servizz awtorizzata għal eżami u/jew tiswija.
  • Tmexxix korda taħt it-twapet. Tgħattix il-korda b'twapet tat-twapet, runners, jew kisi simili. Irranġa l-korda 'l bogħod miż-żona tat-traffiku u fejn ma titfixkelx.
  • Biex tipproteġi kontra xokk elettriku, tgħaddix unità, plagg jew korda fl-ilma jew roxx b'likwidi.
  • Dan il-prodott fih kimiċi magħrufa mill-Istat ta’ Kalifornja li jikkawżaw kanċer u difetti fit-twelid jew ħsara riproduttiva oħra.
  • Dan il-fann huwa maħsub għall-użu fuq ġewwa biss.
  • Keep fingers and other objects away from the fan blades and moving parts during operation.
  • Tiżgura vol xieraqtage (120 Volts) is supplied to the unit.

3. Kontenut tal-Pakkett

Iċċekkja li l-komponenti kollha huma preżenti qabel tibda l-installazzjoni:

  • Air King 9718 Industrial Grade Ceiling Mount Fan
  • Bracket tal-Immuntar tal-Limitu
  • Ħardwer tal-Assemblea
  • Secondary Safety Cable
  • Manwal għall-Utent (dan id-dokument)
Diagram showing fan dimensions, assembly tools, and secondary safety cable

Figure 2: Included components and fan dimensions. Note the secondary safety cable and assembly tools required.

4. Setup u Installazzjoni

Proper installation is crucial for the safe and effective operation of your fan. If you are unsure about any part of the installation process, consult a qualified electrician or contractor.

  1. Agħżel Post tal-Immuntar: Select a ceiling location that can structurally support the fan's weight (approximately 23.1 lbs) and allows for adequate clearance around the fan blades. Ensure the location is within reach of a 120V AC power outlet, considering the 10-foot, 3-conductor type SJT power cord.
  2. Immonta l-Bracket: Securely attach the ceiling mount bracket to a sturdy ceiling joist or structural support using appropriate hardware. Ensure the mounting is firm and stable to prevent vibration or detachment.
  3. Waħħal il-Fan: Carefully lift the fan and attach it to the mounted bracket according to the assembly instructions provided with the hardware. Ensure all connections are tightened.
  4. Install Secondary Safety Cable: As an essential safety measure, attach the secondary safety cable from the fan to a separate, independent structural support point on the ceiling. This cable provides backup security in case the primary mounting fails.
  5. Qabbad l-Enerġija: Plug the fan's 10-foot power cord into a grounded 120V AC outlet. Ensure the cord is routed safely to avoid tripping hazards and is not pinched.
Air King 9718 fan mounted on a ceiling in an office setting, showing the power cord

Figura 3: Eżample of the fan mounted on a ceiling, illustrating the power cord connection.

Air King 9718 fan mounted on a ceiling in a warehouse setting

Figure 4: The Air King 9718 fan installed in a commercial warehouse environment.

5. Istruzzjonijiet Operattivi

The Air King 9718 fan is operated using a pull chain control and features adjustable airflow direction.

  • Mixgħul/Mitfi u Kontroll tal-Veloċità: The fan is equipped with a 3-speed pull chain switch. Pull the chain once for Low speed, a second time for Medium speed, a third time for High speed, and a fourth time to turn the fan Off.
  • Aġġusta tad-direzzjoni tal-fluss tal-arja: The fan head can be manually pivoted up or down, and turned side to side, to direct airflow precisely where needed. Ensure the fan is off before adjusting its position.
Close-up of the fan's pull chain control

Figure 5: Detail of the pull chain for speed and power control.

6. Manutenzjoni

Manutenzjoni regolari tiżgura prestazzjoni ottimali u testendi l-ħajja tal-fann tiegħek.

  • Tindif: Disconnect the fan from the power supply before cleaning. Use a soft, damp cloth to wipe down the exterior surfaces. Do not use abrasive cleaners or immerse the fan in water. The powder-coated steel blade, guard, and mount are designed for easy cleaning.
  • Mutur: The 1/6-horsepower motor is fully enclosed and permanently lubricated, requiring no additional lubrication.
  • Ħażna: If storing the fan for an extended period, ensure it is clean and dry. Store in a cool, dry place.
Close-up of the fan's steel grill and blades, highlighting the durable powder-coated finish

Figure 6: The durable powder-coated steel grill and blades are designed for longevity and easy maintenance.

7 Issolvi l-problemi

ProblemaKawża PossibbliSoluzzjoni
Il-fann ma jaħdimxNo power supply; Power cord not fully plugged in; Pull chain not activated.Check power outlet; Ensure cord is securely plugged in; Pull chain to cycle through speeds.
Fluss ta 'arja mnaqqasFan blades or grill are dirty; Fan is on a lower speed setting.Clean fan blades and grill (ensure fan is unplugged); Adjust speed setting using the pull chain.
Ħsejjes jew vibrazzjonijiet eċċessiviLoose mounting hardware; Fan blades are dirty or unbalanced; Obstruction in fan.Check and tighten all mounting hardware; Clean blades; Ensure no objects are interfering with fan operation. Refer to noise level chart for expected sound levels.
Chart comparing Air King fan sound levels at different speeds to common household noises

Figure 7: Air King 9718 fan sound levels: High 67 dB, Medium 58 dB, Low 49 dB, compared to other sounds.

8. Speċifikazzjonijiet

Numru tal-Mudell9718
BrandRe tal-Ajru
Dijametru tax-xafra tal-fann18 Pulzier
Mutur1/6 Horsepower, Permanently Lubricated
Numru ta' Veloċitajiet3
Kapaċità tal-Fluss tal-Ajru8780 pied kubu fil-minuta (CFM)
Veloċità1500 RPM
Voltage120 Volts
Wattage180 Watts
Noise Level (High)67 Deċibel
Dimensjonijiet tal-Prodott (P x W x H)10.5"D x 24"W x 28"H
Piż tal-oġġett23.1 Liri
MaterjalAzzar Liga (Miksi bit-Trab)
Materjal tax-xafraPlastik
Sors tal-EnerġijaAC Corded
Tip ta 'ImmuntarMuntatura tal-Limitu
Tul tal-kurdun10-foot, 3-conductor type SJT
ĊertifikazzjonijietETL, OSHA Compliant
Air King 9718 fan mounted in a gym, with callouts for 1/6 HP, 120V, and 1.5 Amps

Figure 8: Key electrical specifications and motor details of the fan.

9. Garanzija u Appoġġ

This Air King 9718 Industrial Grade Ceiling Mount Fan comes with a Garanzija Limitata ta' Sena mid-data tax-xiri. Din il-garanzija tkopri difetti fil-materjal u l-abbilità taħt użu normali.

For warranty claims, technical support, or replacement parts, please contact Air King customer service. Keep your proof of purchase for warranty validation.

Do not attempt to repair the fan yourself, as this may void the warranty and pose safety risks.

© 2023 Air King. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.